Theoretical and Measurement Results
figure.10
The theoretical calculations of the model in figure 2 are
compared with experimental measurements of the actual
dipole construction following the same physical
dimensions as what was used and optimized within the
FDTD model. The theoretical calculations in figure 8
are derived from the impulse response and are verified
with experimental measurements on our first physical
model figure 9.
Calculated Return Loss
Impulse Response in Air of FDTD Model
figure.8
Measured Return Loss
figure.11
Measurements
figure.9
figure.12
The impulse response electrical performance relative to
tissue and air is represented in figures 10 & 11
respectively. Several production dipoles were
constructed and measured; the physical dimensions and
respective VNA results are presented in figure 12.
Impulse Response in Tissue