Human MeshesStandard Bio-Meshes
|
|||||||
|
![]() |
![]() |
If greater precision in the human body mesh is required, Remcom also offers High Fidelity human meshes for both full body and head/shoulders regions. These meshes offer unparalleled precision, with an astonishing level of detail, particularly useful for designing implantable devices or in any design situation where anatomical accuracy is crucial. These are provided by Dr. Michael Smith, and Mr. Chris Collins, NMR Hershey .
High Fidelity Male Head/Shoulders Mesh
Made up of 2 mm x 2 mm x 2.5 mm (vertical direction) FDTD
cells, 17 tissue types and an overall mesh size of 309 x 177
x 161 cells. Additional space may be added around the
mesh for insertion of phone handset or other electronic devices.
The mesh size as provided is about 8 million cells and requires
approximately 256 MB of RAM for XFdtd calculation.
High Fidelity Male Body Mesh
Made up of 5 mm cubical FDTD mesh cells, 23 different
tissue types, and an overall mesh size of 136 x 87 x 397 cells.
This mesh as provided is about 4 million cells and requires
roughly 128 MB of RAM for XFdtd calculations.
High Fidelity Female Body Mesh
Made up of 5 mm cubical FDTD mesh cells, 34 unique tissue types, and an
overall mesh size of 135 x 85 x 372 cells. This mesh as provided is
about 4 million cells and requires roughly 128 MB of RAM for XFdtd
calculations.
All three high fidelity meshes include the capability to automatically adjust the permittivity and conductivity of the tissues for any specified frequency between 1 MHz and 20 GHz, saving the user the tedious effort of typing in these parameters for each tissue type in the mesh as the frequency of interest changes. In addition to automatically providing single-frequency tissue parameters, the Human Head and both Human Body meshes also have the ability to make Ultra-Wide-Bandwidth (UWB) calculations for transient electromagnetic fields. An example of this capability is available.
These high fidelity meshes provide highly accurate detail for internal body structures, necessary when internal EM fields are important, for example with implanted medical devices. To protect the intellectual property of both The Hershey Medical Center and Remcom Inc., these meshes are provided in an encrypted format so that they can be used only with XFdtd. The user may modify and save the meshes, but the modified meshes will then be usable only by XFdtd. A special license is provided with each purchase that allows the mesh to be utilized by XFdtd.
Also, it should be understood that these meshes may not be used by organizations which may be competing with the NMR group at Hershey Medical Center for funding or prior publication of research results.
Remcom provides the SAM head as a CAD file which may be oriented and
meshed at any desired resolution within XFdtd.
The CAD file for the SAM model, based on the original data from the
IEEE Standard 1528, was generated and provided by Dr. Wolfgang Kainz
from the U.S. Food and Drug Administration - Center for Devices and Radiological Health.
According to the Federal Communications Commission of the United States as stated in OET Bulletin 65, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields", Supplement C:
Remcom's XFdtd software is based on the FDTD method and is routinely tested for SAR calculation accuracy. Remcom offers the SAM head and Remcom biomeshes in part to aid customers in complying with FCC limits on SAR. The biomeshes are based on measured data. They and the SAM head can provide accurate estimates of SAR when used with a representative XFdtd model of the device. The accuracy of the device model can be established by comparing XFdtd calculations of radiated power to measurements. However, XFdtd and the Remcom biomeshes are not guaranteed to provide SAR calculations that will be acceptable to the FCC and are furnished without liability.
Available for XFdtd are some complimentary animal meshes provided by The Radio Frequency Branch of the Human Effectiveness Division of the Air Force Research Lab at Brooks Air Force Base.
|
|
|
|